Buckleys International Testing Products

Call us on +44 (0)1303 278888

PD40R Roofing/Bridge Deck Test Kit (PD40R)

Part Number: 6002-0035

Product Features

  • Lightweight & portable  
  • Easy to use 
  • Audible & visual alarm fault indicators 
  • Clear backlit LCD display
  • Membrane keypad operation 
  • Automatic voltage selector
  • Accurate sensitivity control
  • Displays electrode DC current
  • Volume control for quiet environments
  • Power limited to avoid coating damage
  • Older PHD accessories can be used
  • One year ‘back-to-base’ warranty
  • Microprocessor controlled 
  • CE approved
Download A Brochure

Our PD40R Flat Roofing/Bridge Deck Holiday Detector Kit has been specifically created to enable inspectors to quickly and effectively test flat roofs, waterproof bridge deck coatings and similar non-conductive coatings for pinholes and porosity.

Buckleys' PD40 holiday detector will test non-conductive membrane thicknesses from 64 microns to 25.6mm. The PD40R kit contains all items required for testing; including a 50m earth extension lead and a 450mm (18”) phosphor bronze brush electrode, suitable for most applications. For ease of transporting, especially on site, the kit is supplied in a high-visibility carrying case which securely holds the unit and all accessories. Batteries can be charged out of the unit by mains or from a car lighter socket or good quality D-cells can be used.

Buckleys' PDR leak detector units can calculate the dielectric strength of a coating and adjust the output voltage automatically. The operator simply needs to input the coating's thickness via the keypad. The test voltage is set according to the NACE SP-02-74 standard. 

Once the holiday detector unit is assembled and set-up, testing is simply a case of passing the electrode over the entire test surface (a bit like using a broom). Defects, porous areas, leaks or holes in the surface will trigger the detector's alarm system as the electrode brush is passed over them

Kit contents

  • PD40 holiday detector unit
  • Battery charger with 4 x rechargeable batteries
  • Power pack
  • Shoulder bag
  • Test probe handle
  • Coiled interconnecting lead
  • 5m earth lead
  • 50m earth extension lead
  • 2 x 460mm extension rods
  • Electrode shoe
  • Screwdriver
  • 450mm phosphor bronze brush electrode
  • Drum-brush electrode
  • Pointed probe
  • Test voltage calculator
  • A calibration certificate is included in the instruction manual
  • All contained in a high-visibility robust carrying case
  • Adjustable output voltage range: 2-40kV DC
  • Adjustable DC alarm sensitivity: 10-450 uA
  • Suitable for coating thicknesses 64µ to 25.6 mm
  • Operating time: 10 hrs (tested as BSEN-50356 @ 40kV Test unit fitted with 10000mAh NiMH cells)
  • Test voltage formula: NACE SP0274
  • Weights:
    (unit, shoulder bag & batteries): 2.0Kg
    (full kit): 12Kg
  • Dimensions:
    (case):    32cm x 28cm x 14cm 
    (unit only):    63cm x 50cm x 22cm
    (full kit, packed): 66cm x 51cm x 23cm
  • Commodity Code: 9027801700

 

No questions are available at this time

Be the first to ask!



Pointed Probe - 75mm long (E910)

75mm long For testing recesses or small areas.   ...

Drum Brush - 150mm long (E912)

150mm long For checking irregular shaped objects.   ...

Roller 500mm (E850)

500mm For testing large flat areas with ease – ideal for use with roofing kits.   ...

Roller Electrode 600mm (E860)

600mm For testing large flat areas with ease – ideal for use with roofing kits.   ...

Roller Electrode 700mm (E870)

700mm For testing large flat areas with ease – ideal for use with roofing kits.   ...

Straight Phosphor-Bronze Brush - 100mm (E104)

Straight Phosphor Bronze Brush Electrodes 100mm / 4" wide  ...

Straight Phosphor-Bronze Brush - 150mm (E106)

Straight phosphor bronze electrodes are used to test large flat areas that are not easily scratched. And are normally supplied with a 90° backing strip for fitting into the shoe attachment (A12). *Maximum length recommended for use with AC equipment is 150mm ...

Straight Phosphor-Bronze Brush - 200mm (E108)

Straight phosphor bronze electrodes are used to test large flat areas that are not easily scratched. And are normally supplied with a 90° backing strip for fitting into the shoe attachment (A12). *Maximum length recommended for use with AC equipment is 150mm ...

Straight Phosphor-Bronze Brush - 250mm (E110)

Straight phosphor bronze electrodes are used to test large flat areas that are not easily scratched. And are normally supplied with a 90° backing strip for fitting into the shoe attachment (A12). *Maximum length recommended for use with AC equipment is 150mm ...

Straight Phosphor-Bronze Brush - 300mm (E112)

Straight phosphor bronze electrodes are used to test large flat areas that are not easily scratched. And are normally supplied with a 90° backing strip for fitting into the shoe attachment (A12). *Maximum length recommended for use with AC equipment is 150mm ...

Straight Phosphor Bronze Brush - 350mm (E114)

Straight phosphor bronze electrodes are used to test large flat areas that are not easily scratched. And are normally supplied with a 90° backing strip for fitting into the shoe attachment (A12). *Maximum length recommended for use with AC equipment is 150mm ...

Straight Phosphor-Bronze Brush - 400mm (E116)

Straight phosphor bronze electrodes are used to test large flat areas that are not easily scratched. And are normally supplied with a 90° backing strip for fitting into the shoe attachment (A12). *Maximum length recommended for use with AC equipment is 150mm ...

Straight Phosphor-Bronze Brush - 450mm (E118)

Straight phosphor bronze electrodes are used to test large flat areas that are not easily scratched. And are normally supplied with a 90° backing strip for fitting into the shoe attachment (A12). *Maximum length recommended for use with AC equipment is 150mm ...

Straight Phosphor-Bronze Brush - 500mm (E120)

Straight phosphor bronze electrodes are used to test large flat areas that are not easily scratched. And are normally supplied with a 90° backing strip for fitting into the shoe attachment (A12). *Maximum length recommended for use with AC equipment is 150mm ...

Straight Silicone Rubber - 100mm (E204)

The straight silicone rubber electrodes are normally supplied with a 90° backing strip, for fitting into the shoe attachment (A12). They can also be supplied with a 45° backing strip to enable the electrode to be connected directly to an extension rod, or with the Adaptor (A4), straight ont...

Straight Silicone Rubber - 150mm (E206)

The straight silicone rubber electrodes are normally supplied with a 90° backing strip, for fitting into the shoe attachment (A12). They can also be supplied with a 45° backing strip to enable the electrode to be connected directly to an extension rod, or with the Adaptor (A4), straight ...

Straight Silicone Rubber - 200mm (E208)

The straight silicone rubber electrodes are normally supplied with a 90° backing strip, for fitting into the shoe attachment (A12). They can also be supplied with a 45° backing strip to enable the electrode to be connected directly to an extension rod, or with the Adaptor (A4), straight ...

Straight Silicone Rubber - 250mm (E210)

The straight silicone rubber electrodes are normally supplied with a 90° backing strip, for fitting into the shoe attachment (A12). They can also be supplied with a 45° backing strip to enable the electrode to be connected directly to an extension rod, or with the Adaptor (A4), straight ont...

Straight Silicone Rubber - 300mm (E212)

The straight silicone rubber electrodes are normally supplied with a 90° backing strip, for fitting into the shoe attachment (A12). They can also be supplied with a 45° backing strip to enable the electrode to be connected directly to an extension rod, or with the Adaptor (A4), straight ont...

Straight Silicone Rubber - 350mm (E214)

The straight silicone rubber electrodes are normally supplied with a 90° backing strip, for fitting into the shoe attachment (A12). They can also be supplied with a 45° backing strip to enable the electrode to be connected directly to an extension rod, or with the Adaptor (A4), straight ont...

Straight Silicone Rubber - 400mm (E216)

The straight silicone rubber electrodes are normally supplied with a 90° backing strip, for fitting into the shoe attachment (A12). They can also be supplied with a 45° backing strip to enable the electrode to be connected directly to an extension rod, or with the Adaptor (A4), straight ont...

Straight Silicone Rubber - 450mm (E218)

The straight silicone rubber electrodes are normally supplied with a 90° backing strip, for fitting into the shoe attachment (A12). They can also be supplied with a 45° backing strip to enable the electrode to be connected directly to an extension rod, or with the Adaptor (A4), straight ont...

Straight Silicone Rubber - 500mm (E220)

The straight silicone rubber electrodes are normally supplied with a 90° backing strip, for fitting into the shoe attachment (A12). They can also be supplied with a 45° backing strip to enable the electrode to be connected directly to an extension rod, or with the Adaptor (A4), straight ont...

Straight Silicone Rubber - 600mm (E224)

The straight silicone rubber electrodes are normally supplied with a 90° backing strip, for fitting into the shoe attachment (A12). They can also be supplied with a 45° backing strip to enable the electrode to be connected directly to an extension rod, or with the Adaptor (A4), straight ont...

© 2017 All Rights Reserved Buckleys (UVRAL) Ltd